A New Diagnostic Method of Bolt Loosening Detection for Thermal Protection Systems

Weihua Xie,Songhe Meng,Jiecai Han,Shanyi Du,Boming Zhang,Dong Yu
DOI: https://doi.org/10.1117/12.843778
2009-01-01
Abstract:Research and development efforts are underway to provide structural health monitoring systems to ensure the integrity of thermal protection system (TPS). An improved analytical method was proposed to assess the fastener integrity of a bolted structure in this paper. A new unsymmetrical washer was designed and fabricated, taking full advantage of piezoelectric ceramics (PZT) to play both roles as actuators and sensors, and using energy as the only extracted feature to identify abnormality. This diagnostic method is not restricted by the materials of the bracket, panel and base structure of the TPS whose condition is under inspection. A series of experiments on a metallic honeycomb sandwich panel were completed to demonstrate the capability of detecting bolt loosening on the TPS structure. Studies showed that this method can be used not only to identify the location of loosened bolts rapidly, but also to estimate the torque level of loosening bolts. Since that energy is the only extracted feature used to detect bolt loosening in this method, the diagnostic process become very simple and swift without sacrificing the accuracy of the results.
What problem does this paper attempt to address?