Bolt Loosening Detection Based on Piezoelectric Active Sensing Technology*

Tao WANG,Yi LUO,Shaopeng LIU,Han XIAO,Zhigang WANG,Yourong LI
DOI: https://doi.org/10.3969/j.issn.1004-1699.2013.08.005
2013-01-01
Abstract:For the measurement of bolt axial force and detection of bolt loosening,the ultrasonic method is studied using the piezoelectric active sensing technique. When the ultrasonic wave generated by a piezoelectric patch propagates across the interface of the components jointed by the bolt,only part of the ultrasonic wave energy passes through it. The transmitted wave energy depends on the true contact area which is decided by the bolt pretension ac-cording to the Classical Hertz contact theory. By measuring the received energy with another piezoelectric patch on the other side of the connected components, the bolt pretension or bolt connection status can be detected. The experiment device is set up and serials experiments were carried out. The experiment results show that the wave energy propagated across the interface has good correlation with the torque level. This method has potential application for the monitoring of bolt loosening in-site.
What problem does this paper attempt to address?