Macro modeling method for electrostatic-drive silicon diaphragm

Xiezhao Lin,Ji Ying,Zichen Chen
2008-01-01
Abstract:The macro modeling method for Micro-electro-mechanical System (MEMS) devices is a key issue in the design and simulation of MEMS system. For establishing the macro model of the nonlinear silicon diaphragm drived by a distributed electrostatic force, a nonlinear function fitting scheme was used to calculate the energy data after finite element analysis for establishing an analytical model of kinetic energy, strain energy and electrostatic co-energy of the system. Then, all these energy functions were represented in the term of general mode coordinates and were subjected into the Lagrange equation to deduce the motion equations of the silicon diaphragm. Thus a macro model was obtained to simulate the quasi-static and dynamic characteristics of the device. By comparing the macro model and the finite element calculating, it concludes that the macro model can capture the quasi-state and dynamic behaviors of the electrostatic drive device quite well. And this modeling method can consider the effects of residual stress and nonlinear geometry and can reduce lots of computational cost.
What problem does this paper attempt to address?