Effect Of Discharge Parameters And Control Of Spark Breakdown In Degradation Of Phenol By Pulsed Streamer Corona Discharge

Yongjun Shen,Minghua Zhou,Lecheng Lei
2006-01-01
Abstract:The energy consumption and its conversion efficiency in the pulse corona discharge were analyzed and calculated from the discharge parameters. The cause of the spark breakdown in corona discharge was analyzed. The energy conversion efficiency from the power supply to the corona streamer reactor during the wavelength time was roughly 78%. In the rest time the wave trail declined slowly to the residual voltage. The wave trail voltage with the RC leakage circuit was much lower than that having no RC leakage circuit. The degradation efficiency of phenol had little change, demonstrating that the energy consumption of the leakage circuit was not much, and most of the energy was used to degrade phenol. It also demonstrated that the leakage circuit was successful. This is an abstract of a paper presented at the 231st ACS National Meeting (Atlanta, GA 3/26-30/2006).
What problem does this paper attempt to address?