Degradation Of Phenol In Aqueous Solution By High-Voltage Pulsed Corona Discharge

Yongjun Shen,Minghua Zhou,Lecheng Lei,Wei Li.,Yao Shi
2005-01-01
Abstract:High-voltage discharge parameters affecting the degradation efficiency of phenol and TOC in aqueous solution, e.g., pulse peak voltage, the discharge distance between the electrodes, were studied. The energy conversion efficiency from the power supply to the corona streamer during the wavelength time was roughly 78%. For the rest of the time, the wave trail declined slowly to the residual voltage. The wave trail voltage with the RC leakage circuit was much lower than that without RC leakage circuit. The degradation efficiency increased with peak voltage. The pulse peak voltage increase led to increment of the pulse energy, so the energy in the wastewater system increased and the concentration of the discharge resultants (high energy electrons, ozone, and UV) was higher. The degradation efficiency decreased from 48.6 to 33.2% while the distance between the two electrodes increased from 30 to 50 mm. The longer the distance between the two electrodes, the more energy needed to format the plasma channel, which led to the energy that was used to degrade the phenol being decreased. This is an abstract of a paper presented at the 229th ACS National Meeting (San Diego, CA 3/13-17/2005).