Degradation of Aqueous Phenol by High Voltage Pulsed Corona

高翔,秦鹏,吴祖良,骆仲泱,岑可法
DOI: https://doi.org/10.3785/j.issn.1008-973x.2010.02.018
2010-01-01
Abstract:The experiment of aqueous phenol degradation was conducted using high voltage pulsed corona discharge in a needle-cylindrical reactor.The influences of Fe~(2+)addition,pulsed voltage peak value,pulsed frequency,additional gas and pH value on the degradation of phenol were investigated.Results showed that phenol degradation rate firstly increased but then decreased with the increase of Fe~(2+)addition.The optimal concentration of Fe~(2+)was 0.015 mmol/L.The degradation rate of phenol improved with the increase of the pulsed voltage,the pulsed frequency,the flow of the additional gas and the pH value.40kV peak pulsed voltage,180 Hz pulsed frequency,6 L/min additional oxygen gas were the best economical reactive conditions,and the phenol degradation rate reached 84.8%.Alkaline environment was beneficial to the degradation of phenol.The species of additional gases greatly influenced the phenol degradation.The degradation rates of phenol from high to low were with additional gas of Ar,O_2 and N_2.The degrada-tion rate of aqueous phenol reached 98.1% with additional gas of Ar.
What problem does this paper attempt to address?