Scale-up investigation on pulse corona for the removal of toluene

Yong Nie,Yao Shi,Wei Li.,Xin Wang,Jianjun Ruan,Tianen Tan
2003-01-01
Abstract:The scale-up experiments of the decomposition of toluene by pulse corona discharge in wire-plate reactor were investigated. The maximum input power of pulse voltage source and the maximal peak voltage was 1kW and 100kV, respectively. The experiments were conducted with a gas-flow rate of 4similar to16m(3.)h(-1). Some parameters, such as peak voltage, pulse frequency, initial concentration of toluene, gas-flow rate, which influenced on removal efficiency, have been investigated. The results showed that the removal efficiency was improved obviously when the peak field intensity changed in the range of 9similar to12.5kV(.)cm(-1); the removal efficiency was up to 64% when gas-flow rate, peak voltage, initial concentration of toluene, pulse frequency were 4m(3.)h(-1), 73kV, 277mg(.)m(-3), 200pps, respectively; the energy yield of toluene was 3g(.)(kWh)(-1). A dynamics model was developed to describe the relation of the removal efficiency of toluene with energy density and initial concentration of toluene. The decomposition rate constant of toluene was 0.00353. According to the results, the optimization design for the reactor and the matching of pulse voltage source can be reckoned.
What problem does this paper attempt to address?