Abstract:A novel FGD process was proposed, in which organic amine is used as absorbent to absorb the sulfur dioxide in flue gas. The vapor-liquid equilibrium model of absorption of sulfur dioxide in flue gas by organic amine was established, and the vapor-liquid equilibrium of sulfur dioxide-ethylene diamine-phosphoric acid-water system was predicted. Comparing the predicted results with the experimental results for a 0.3mol?L?1 ethylene diamine-phosphoric acid solution system, the relative error is less than 7 percent. By using ethylene diamine/phosphoric acid aqueous solution as absorbent and a φ 30mm×600mm packed tower in the lab, the suitable technical conditions of SO2 absorption and deabsoption were experimentally searched. Results show that the suitable conditions are as following: for absorption; the ratio of liquid to gas L/G is 0.6~1.0 L?m?3, concentration of ethylene diamine in absorbing solution is 0.3mol?L?1, residual SO2 concentration in the desorbed liquid used as absorbent is 4~6g?L?1, pH value is 6.0~7.5; for deabsorption; the feed temperature is 60°C, the bottom temperature of the deabsorption tower is 103°C, liquid flow rate is 0.7m3?m?2?h?1, and the concentration of SO2 in the feed-in liquid is 14~16g?L?1. Several wet FGD methods for a 200MV power plant were economically analyzed and compared. Unit FGD expense of the proposed novel method is one third of that of limestone-gypsum method and is also lower than that of Ammonia method and NADS method.