THE EXPERIMENTAL STUDY OF HYDROGEN AND AIR PREMIXED COMBUSTION IN MICROSCALE T STYLE TUBE

ZHANG Yong-sheng,ZHOU Jun-hu,YANG Wei-juan,LIU Mao-sheng,CEN Ke-fa
DOI: https://doi.org/10.3321/j.issn:0258-8013.2005.21.023
2005-01-01
Abstract:This paper describes the hydrogen and air premixed combustion in microscale T style tube and finds this structure be helpful for stable burning. It draws some conclusions about flame temperature, flux, hydrogen-air equivalence ratio and combustion efficiency. The stable burning can be observed when the premixed gas velocity changed from 0.57 m/s to 18.4 m/s in suitable hydrogen-air equivalence ratio. It is easy flameout for the heat loses influence distinctly when the premixed gas flux is small. The highest flame temperature be measured when the hydrogen-air equivalence ratio change between 0.6 and 0.8. In certain hydrogen flux, there is a highest combustion efficiency nearby the completely combustion equivalence ratio, and the combustion efficiency near to 100%. When the hydrogen flux is 183 × 10-4 Nm3/h and completely combustion, the heat loses for the level part of the T style tube is 27% of the heat of reaction.
What problem does this paper attempt to address?