RESEARCH AND ENGINEERING APPLICATION ON SOLVING SLAGGING PROBLEM OF HEXAGONAL TANGENTIALLY FIRED BOILER

赵玉晓,李瑞扬,孙斌,吕薇,秦裕琨
DOI: https://doi.org/10.3321/j.issn:0258-8013.2004.07.044
2004-01-01
Abstract:In order to solve the slagging problem happened on the water-cooled wall and super-heater at the exit of furnace of a hexagonal tangentially fired boiler burning pulverized coal, based on the experience and research achievement of quadrangular tangentially fired boiler, the jet deviation and the reason causing slagging were analyzed theoretically, a PDA (Particle Dynamics Analyzer) cold model experiment of gas-solid two-phase flow near burner zone was also proceeded, and then a retrofit proposal of engineering technology was put forwarded which achieved a good engineering application. Research results show that adopting homocentric two tangential circles of primary air and secondary air properly can improve the flow field distribution in furnace effectively, thus, the slagging of heat-transfer surface is controlled.
What problem does this paper attempt to address?