Performance Analysis of the Two Stage Heat Transformer

尹娟,史琳,王鑫,朱明善
DOI: https://doi.org/10.3969/j.issn.1005-0329.2000.08.016
2000-01-01
Abstract:The efficiency of low grade energy transfor was compared using three kinds of two stage heat transformers. The best two stage heat transformer couples the first stage absorber to the second stage evaporator. And the thermal performance of this system was analyzed in detail. The results show that the two stage heat transformer can reach a higher useful temperature and has a wider working range, but has a lower efficiency than the single stage heat transformer. Based on the analysis of different working fluids, a new two stage heat transformer using H2O/LiBr solution in the first stage and TFE/NMP in the second stage was proposed to obtain a higher temperature lift and better efficiency.
What problem does this paper attempt to address?