Operational experience with forced cooled superconducting magnets

Denis P. Ivanov,Boris N. Kolbasov,I. O. Anashkin,P. P. Khvostenko,Wanjiang Pan,Subrata S. Pradhan,Ashoo N. Sharma,Yuntao Song,Peide Weng
DOI: https://doi.org/10.1016/j.fusengdes.2013.02.094
IF: 1.905
2013-01-01
Fusion Engineering and Design
Abstract:Force-cooled concept has been chosen for ITER superconducting magnet to get reliable coil insulation using vacuum-pressure impregnation (VPI) technology. However 17 breakdowns occurred during operation of six magnets of this type or their single coil tests at operating voltage < 3 kV, while ITER needs 12 kV. All the breakdowns started on electric, cryogenic and diagnostic communications (ECDCs) by the high voltage induced at fast current variations in magnets concurrently with vacuum deterioration, but never on the coils, though sometimes the latter were damaged too. It suggests that simple wrap insulation currently employed on ECDCs and planned to be used in ITER is unacceptable. Upgrade of the ECDC insulation to the same level as on the coils is evidently needed. This could be done by covering each one from ECDCs with vacuum-tight grounded stainless steel casings filled up with solid insulator using VPI-technology. Such an insulation will be insensitive to in-cryostat conditions, excluding helium leaks and considerably simplifying the tests thus allowing saving time and cost. However it is not accepted in ITER design yet. So guarantee of breakdown prevention is not available. © 2013 Elsevier B.V.
What problem does this paper attempt to address?