Tryout of the vacuum impregnation procedure for the ITER PF1 coil on the VPI mold made of plastic shell

S Grigoriev,I Rodin,V Tanchuk,S Korban,A Bursikov,A Mednikov,A Pugachev
DOI: https://doi.org/10.1088/1742-6596/507/3/032019
2014-05-12
Journal of Physics: Conference Series
Abstract:The PF1 Coil as part of the ITER superconducting magnet system is intended for positioning and shaping of the magnetic poloidal field. The technical specification for the PF1 coil requires a full-scale simulation of the basic technological processes including vacuum pressure impregnation (VPI). Usually, a VPI mold is made of massive stainless steel walls to get the required quality of the monolithic structure of the pancake insulation by hot-curing compound. As a result, we obtain a high-cost furnace with a considerable amount of steel inside to be heated up to the specified temperature; excessive energy consumption for the furnace heating system; problems with the vacuum tightness of the VPI mold. The impregnation procedure using a VPI plastic mold was proposed so as to avoid the above mentioned shortcomings associated with the use of the furnace made of stainless steel.
English Else
What problem does this paper attempt to address?