Study on Heat Transfer Performance of an Aluminum Flat Plate Heat Pipe with Fins in Vapor Chamber

Hao Peng,Juan Li,Xiang Ling
DOI: https://doi.org/10.1016/j.enconman.2013.05.004
IF: 10.4
2013-01-01
Energy Conversion and Management
Abstract:The heat transfer performance of a novel flat plate heat pipe (FPHP) for electronic cooling was investigated experimentally. A variety of performance tests of FPHP were carried out with different air flow velocities (1.5 m/s < u < 6 m/s), working fluid filling ratios (10% < FR < 50%), and the vacuum degrees (0.002 Pa < VD < 0.25 Pa). Using distilled water and acetone as working fluids, the influence of the above parameters on steady-state heat transfer characteristics of the FPHP was also examined. The experimental results indicated that the filling ratio and vacuum degree had a significant influence on thermal performance of FPHP. Compared with cooling performance using distilled water and acetone, the FPHP cooling component using acetone had a stronger heat dissipation capacity for the same filling ratio. (C) 2013 Elsevier Ltd. All rights reserved.
What problem does this paper attempt to address?