Process calculation of mechanical ventilation prilling tower for ammonium nitrate

Yang WANG,Xiao-wei JIANG,Hao YUAN
DOI: https://doi.org/10.3969/j.issn.1005-9954.2013.10.016
2013-01-01
Abstract:The calculation process of prilling unit in the ammonium nitrate prilling tower was introduced. Through the theoretical process calculation of prilling unit, the specifications of the mechanical ventilation prilling tower were determined, followed by a comparison with the data of actual running devices for validation. The theoretical height of the tower was calculated based on the heat-transfer physical parameters of each corresponding zone where the ammonium nitrate particles freely fall through the tower; the tower diameter was determined by calculating the hitting point of particles onto the tower wall based on kinematic equations. The reasonableness of the calculation was verified by the running device, and part of the equations involved in the calculation process of the prilling tower were analyzed combined with the actual operation of the project equipment, discussing the impact of the key parameters on the design of prilling tower. This makes guidance and reference for the design and checking for prilling tower.
What problem does this paper attempt to address?