Factors effecting mass transfer rates for air stripping of ammonia in multi-face-ball packed tower from ammonia-nitrogen wastewater

WANG Hai-tao,ZHOU Kang-gen,PENG Jia-le,HU Yuan-juan
2012-01-01
Abstract:The removal and recovery of concentrated ammonia from ammonia-nitrogen wastewater from a vanadium extraction process were studied. An air stripping system was built, consisting of multi-face-ball packed stripping tower and adsorption tower, and pipe line system for circulation of the wastewater, adsorption solution and stripping air. The effects of factors such as flow rate, temperature and pH value of the wastewater, flow rate and pH value of HCl adsorption solution, and air flow rate on mass transfer rate of ammonia were investigated. The results show that under the best conditions of stripping and absorption processes, the ammonia stripping mass transfer coefficient K L is 7.2 mm/h.
What problem does this paper attempt to address?