Abstract:A full scale study was conducted to evaluate the removal efficiency of combined treatment process,which consists of biological pretreatment,conventional treatment and advanced treatment,on contaminated raw water with high ammonia nitrogen and high organic pollutants.It was found that the ammonia nitrogen was mostly removed by biological pretreatment and biological activated carbon,and the temperature of water was an important factor.The removal efficiency of combined treatment process on CODMn was higher than TOC.Sedimentation and biological activated carbon were two important processes for the removal of organic pollutants.Turbidity and iron ion were removed effectively by sedimentation,and the average removal rates were larger than 95%.The removal rate of manganese ion by sedimentation was 50.9%.