Pretreatment of Light-polluted Raw Water by Biological Active Carbon Expended Bed

ZHANG Shan-li,LIU Hong,LI Qi-jun,Shvetsov V,Morozova K,WANG Zhan-sheng
DOI: https://doi.org/10.3321/j.issn:1672-2043.2005.05.031
2005-01-01
Abstract:Active carbon can not only absorb organics but also provide space for microorganism to attach in, thus can supply enough time for microorganism to remove sustainable organics. A reactor with volume of 150 liters was build at Sanjiadian reservoir(Downstream of Guanting, Beijing)to study the removal effects of organics and ammonia in light-polluted water by biological active carbon expended bed (BAC-EB). When the water temperature was 1.5 ℃~21 ℃, the concentrations of influent CODMn and ammonia were 4.46~6.58 mg·L-1 and 0.14~0.39 mg·L-1 respectively. The reactor had a satisfactory startup with CODMn removal rate about 70% due to the absorption of active carbon. The removal of organics and ammonia were quite approving under normal temperature (about 15℃) and low temperature (about 4℃), with the CODMn removal rates of 20% and 10% respectively. UV410 and UV254 were also removed quite noticeably, the removal rates both being 20%~30%. Effluent CODMn and ammonia concentration met the GB standard for Class II and Class I for surface water respectively. During long period running, the reactor wasn't affected by the hydraulic compact, but it could not remove insoluble organics. Under low ammonia supplying, higher hydraulic load increased the CODMn removal rate and decreased the startup or re-startup period.
What problem does this paper attempt to address?