Pretreatment of Urban Polluted River Water by Biological Aerated Filter

TAN Nanzhong,WU Weizhong,LI Desheng,SHEN Zhiqiang,YANG Li,CHEN Jiali
DOI: https://doi.org/10.3969/j.issn.1674-5906.2011.04.022
2011-01-01
Abstract:Two-stage of Biological aerated filter bed was used in serie for pretreatment of the water of Xin Yunliang River.The removal effect of CODCr and ammonia was studied in the experiment in winter at low temperature,and the pH value was also monitored.The results showed that at influent flow rate of 2.4 m3?d-1,water tempreture of 13~16 ℃,the CODCr between 66.46~107.82 mg·L-1,the ammonia nitrogen between 22.15~30.68 mg·L-1 and the effluent dissolved oxygen of not less 3.5 mg·L-1,the removal rate of CODCr and ammonia nitrogen were 36.08%~50.37% and 76.98%~93.56% respectively.In the two-stage biological aerated filter,the concentration of nitrogen nitrogen increased significantly and there was no nitrite nitrogen accumulated.The total removal of the total nitrogen was 19.56%,and it could be considered the result of simultaneous nitrification and denitrification.The pH value fluctuated between 7~8.The good removal effect for the CODCr and ammonia nitrogen provided suitable conditions for further biological treatment.
What problem does this paper attempt to address?