Abstract:A pilot-scale test to remove seasonally affected ammonia nitrogen and organic matters from raw water was carried out in a multi-functional filter with activated anthracite in southern China.The test scale was 120 m3/d,filtration speed was 8 m/h and average NH3-N concentration of raw water was around 3.1 mg/L.The results showed that insufficient DO in the influent led to a higher NH3-N concentration in the effluent than the Standards for Drinking Water Quality(GB 5749-2006),along with the accumulation of NO-2-N.Pure oxygen aeration could enhance the removal performance of the filter.The average concentrations of NH3-N and NO-2-N in the effluent were less than 0.1 mg/L and almost zero when DO in the influent got up to 11.9 to 13.6 mg/L,respectively.NH3-N was totally converted into NO-3-N,and the average ratio of degraded NH3-N and DO was 1 ∶ 4.49.The removal rates of NH3-N,CODMn and UV254 were 97%,44% and 44%,respectively.