TREATMENT AND REUSE OF NICKEL PLATING RINSING WATER BY ION EXCHANGE PROCESS

Hang-jun SHEN,Yang XIA,Yue-ping YANG
DOI: https://doi.org/10.3969/j.issn.1000-3770.2006.10.013
2006-01-01
Abstract:In this paper are introduced the treatment and reuse of nickel plating rinsing wastewater by AC column-cation column-anion column-mixed column technological process.The affecting factors for working exchange capacity and regeneration parameters of cation resin are studied with investigation focused on stability of the process operating and the conditions of effluent water quality.It is showed that pH value,Ni2+ concentration and hardness would affect the exchange capacity of cation resin;the regeneration of cation resion with 10% sulphuric acid solution of 4 times resin volume has better effect.After treating,the effluent quality is stable;conductivity rate is below 10μS/cm;pH is within 6~8,and Ni2+ is undetectable;the effluent can be used fully as cleaning water;the nickel sulphate of the regenerated product possesses reuse value.
What problem does this paper attempt to address?