Study on the performance of EDI device in dealing with Ni2+solution with dilute departments filled with cation exchange resins

Yubiao Niu,Xiaoqing Xu,Haiyang Zhao,Zhijun Zhou
DOI: https://doi.org/10.3969/j.issn.1009-1742.2014.07.011
2014-01-01
Engineering Science
Abstract:Study-on-the-feasibility-of-electrodeionization-(EDI)-device,whose-dilute-depart-ments-were-filled-with-cation-exchange-resins-and-feed-water-was-low-concentration-Ni2+solu-tion,for-the-treatment-of-low-concentration-heavy-metal-wastewater.-The-effects-of-operating-voltage-and-dilute-flow-flux-on-the-separation-performances-EDI-processes-were-investigated.-With-the-feed-solution-whose-Ni2+concentration-was-50-mg/L-and-pH-was-4.5,the-results-show-that-the-out-dilute-Ni2+concentration-was-lower-than-2-mg/L-and-the-Ni2+concentration-of-out-concentrate-could-higher-than-900-mg/L-when-operating-voltage-was-25-V-and-dilute-flow-flux-was-20-L/h.
What problem does this paper attempt to address?