Combined RO-EDI process for treatment of nickel in water

ZHENG Ying-han,Hao Wu,CHEN Sheng-ying,CHEN Xue-ming
DOI: https://doi.org/10.3785/j.issn.1008-9497.2012.01.018
2012-01-01
Abstract:The combined reverse osmosis and electrodeionization (RO-EDI) process was used for treating nickel in water under different operational conditions. Experimental results showed that this combined process had high efficiency in purifying the nickel-containing wastewater. It could reduce the Ni 2+ concentration from initial 200 mg · L -1 to lower than 0.5 mg · L -1. The optimum operational conditions are: apressure of 1.5 MPa for RO; a Ni 2+ concentration of 1600 mg · L -1 in the RO concentrate; and a current density of 7.5 A · cm -2 and a hydraulic retention time of 4min for EDI.
What problem does this paper attempt to address?