A Comparative Study Of Nickel(Ii) Removal From Electroplating Wastewater By Pre-Precipitation Combined With Fenton-Precipitation Or Fenton-Like-Precipitation

Yan Liu,Wenwen Ding,Yanzong Zhang,Fei Shen,Gang Yang,Yan He,Lilin Wang,Ling Luo,Xiaohong Zhang,Shihuai Deng
DOI: https://doi.org/10.5004/dwt.2020.25223
IF: 1.1
2020-01-01
Desalination and Water Treatment
Abstract:High nickel(II) electroplating wastewater is difficult to remove through traditional processes. A combined process, which was pre-precipitation, combined with Fenton-like-precipitation or Fenton-precipitation reaction, for treating high nickel complexing wastewater was investigated in this paper. The pre-precipitation pH, initial concentrations of Fe2+ or Fe3+ and H2O2, oxidation reaction pH, and precipitation pH were investigated, and the degradation processes of organic compounds in the treatment were analyzed. Results indicated that the combination of the two processes can effectively remove the high nickel ions. At the optimal experimental conditions, nickel(II) concentrations can be reduced from 2,240 to 0.25 mg/L or 0.31 mg/L by the pre-precipitation combined with Fenton-like-precipitation or Fenton-precipitation process. It demonstrated that the combination of the two processes is an economically and environmentally friendly process to remove the metal from the electroplating wastewater.
What problem does this paper attempt to address?