Hydrogen Blister Formation on Cold-Worked Tungsten with Layered Structure

D Nishijima,T Sugimoto,MY Ye,N Ohno,S Takamura
DOI: https://doi.org/10.1143/jjap.44.380
IF: 1.5
2005-01-01
Japanese Journal of Applied Physics
Abstract:Low-energy (<100 eV) and high-flux (>1021m-2s-1) hydrogen plasma exposures were performed on cold-worked powder metallurgy tungsten (PM-W), recrystallized cold-worked PM-W and hot-worked PM-W. Large blisters with a diameter of approximately 100–200 µm were observed only on the surface of cold-worked PM-W. The blister formation mechanism has not been clarified thus far. PM-W has a consisting of 1-µm-thick layers, which is formed by press-roll processing. A detailed observation of the cross section of those blisters shows for the first time that the blisters are formed by cleaving the upper layer along the stratified layer. These experimental results indicate that the manufacturing process of tungsten material is one of the key factors for blister formation on the tungsten surface.
What problem does this paper attempt to address?