Effects of the Setup Error on the Physics Dose for Nasopharyngeal Carcinoma Undergoing the Intensity Modulated Radiation Therapy

SHEN Jun-shu,ZHU Xi-xu,Li Bing,ZHAI Zhen-yu,ZHANG Yi-qin
2008-01-01
Abstract:Objective: To measure the setup error undergoing the radiation therapy for head-neck neoplasms,and to analyze the effect of the setup error on the physics dose of targets and peripheral organs at risk(OAR)for nasopharyngeal carcinoma(NPC)undergoing the intensity modulated radiation therapy (IMRT). Methods: Seventy-six patients with head-neck neoplasms were choosed at random,measured the setup errors through comparing their digital portal films with their digitally reconstructed radiographs(DRR). Other ten NPC patients in hospital were choosed,simulated the patients' three-dimensional errors in actual therapy on the treat planning system (TPS),and recalculated their dose distribution. We analyzed a series of relative targets and OAR dose parameters,obtained the impact of the setup errors on the physics dose. Results: The setup errors were (-0.62±1.46) mm,(-0.41±1.54) mm and(-0.31±1.67) mm in left-right,cranial-caudal and ventral-dorsal directions respectively. If the setup errors exceed 3 mm,they have statistics signification (P0.05) for GTV in low dose,few parameters in CTV,and spinal cord and brainstem in ventral-dorsal direction. Conclusions: For the patients with NPC undergoing the IMRT,the setup errors should be controlled within 3 mm. So in the daily work,a series of strict QA and QC work through EPID(electronic portal imaging device) is very important.
What problem does this paper attempt to address?