Application of chest positioning reference line combined with infrared positioning system in intensity-modulated radiotherapy for nasopharyngeal carcinoma

Xiaomei YANG,Kaiyue CHU,Jianhua JIN,Yun GE,Jianting WU,Yongliang ZHAO
DOI: https://doi.org/10.3969/j.issn.1005-202X.2017.02.007
2017-01-01
Abstract:Objective To verify whether the chest positioning reference line combined with an infrared positioning system (OPS) helps to reduce the linear and rotational errors in intensity-modulated radiotherapy (IMRT) for nasopharyngeal carcinoma (NPC).Methods Sixty NPC patients were randomized into two groups to receive IMRT with two positioning strategies using chest positioning reference line combined with OPS (30 cases) or conventional positioning (30 eases).All the patients were immobilized with thermoplastic head-and-shoulder mask.Before the scanning,the patients with chest positioning reference line combined with OPS were asked to lie on the positioning bed in a supine position adjusted according to the position of the thermoplastic mask and the head-and-shoulder fixation plate;the chest reference line was determined and then traced with OPS positioning balls.In patients with conventional positioning,the position of the patients was adjusted according to the reference lined defined by the position of the body relative to the fixation plate.Intensity-modulated treatment plans were carried out using the treatment planning system (TPS) after contrast CT scans.The linear and rotational errors of the two positioning methods were analyzed using kilovoltage cone-beam CT scans.Results The linear and rotational errors of positioning in the right-left (X),superior-inferior (Y),and anterior-posterior (Z) directions were calculated in the two groups using the bone registration and gray plus rotation registration algorithms.The linear errors in X,Y,and Z directions were (-0.21± 1.13),(0.14± 0.90),and (-0.31±1.12) mm in chest reference line group,and were (-0.59±1.76),(0.76±1.60),and (-0.41±2.13)mm in conventional positioning group,respectively,and the errors showed significant differences between the two groups (P=0.664 000,0.000 038,and 0.421 000,respectively).The rotational errors in X,Y,and Z directions also differed significantly between the two groups (0.23°±0.61° vs 0.85°±1.31°,P=0.000 150;0.35°±0.42° vs 0.47°±0.61°,P=0.054 200;and 0.11°± 0.72° vs 0.91°±1.32°,P=0.000 430,respectively).Conclusion The application of chest positioning reference line with OPS can effectively reduce random errors in positioning of the patients for IMRT to ensure the accuracy and repeatability of positioning and improve the precision of radiotherapy.
What problem does this paper attempt to address?