Parameter determination of primary air fan for 1 025 t/h-class CFB boiler

ZHANG Man,BIE Ru-shan
2009-01-01
Abstract:In order to provide the parameter determination method of primary air fan for 1 025 t/h-class CFB boiler, the theoretical research and field measurement were performed on several boilers. Based on these, the determination method was proposed, including the air flow of primary air fans should be 120% as much as that of BMCR flow; the pressure head mainly depends on the designed operation condition (TB point) with the consideration of low-load condition, BMCR condition and bed flop condition; the margin of pressure head can be determined based on different conditions. This method has been used in the engineering practice and has significant advantages over conventional determination method, such as lower pressure head, safe and reliable operation and less plant power consumption.