A New Method of Harmonic Current Detection for Three-Phase Unbalanced System

李娟,张波,龙隽,陈斌
DOI: https://doi.org/10.3969/j.issn.1672-9560.2006.10.024
2006-01-01
Abstract:The paper proposes a novel method of harmonic current detection for three-phase unbalanced system,which can detect the positive,negative and zero-sequence components of any term harmonic current precisely.While not adopting the symmetrical compo- nents method directly,the three-phase current is transformed to generalized d_k-q_k coordinate firstly,then filtered by low pass filter and inverse transformation,therefore the positive sequence component is detected.Only change the phase sequence from a-b-c to a-c-b,the negative component can be detected similarly.Meanwhile,the zero-sequence component is decomposed and filtered by low pass filter to obtain the zero-sequence component of any term harmonic current.Finally,sum the three components correspondingly to obtain the de- tect result.The simulation result shows that this method can detect any term harmonic current effectively and precisely nevertheless the distortion and asymmetry of three-phase system.It can also be used as the detection of active and reactive components of fundamental current It can be widely applied to fault detection,protection for power system and active power filter.
What problem does this paper attempt to address?