Research on Magnetic Field of Current Transformer under Non Uniformly-Distributed Equal Ampere-turns Test

ZHANG Hao,ZHAO Wei,QU Kai-feng,JIANG Bo,HUANG Song-ling,YANG Peng
DOI: https://doi.org/10.3969/j.issn.1003-3076.2008.01.010
2008-01-01
Abstract:The non uniformly-distributed equal ampere-turns test,which concentrates the primary turns on one part of the current transformer's core,was presented to measure the error of current transformer in actual working environment.However,there's few or no special research on this method of test at home and abroad up to now.In this paper,3D non-working magnetic field and resultant magnetic field of current transformer's core under non uniformly-distributed equal ampere-turns test are solved with 3D finite element method to reveal the principle of this method of test.The trends of these magnetic fields about primary turns' concentrated angle on current transformer's core are also analyzed.It has indicated that the magnetic field of current transformer's core caused from the change of primary turns' concentrated angle on the core could simulate the stray magnetic field of the core caused from the external currents and short circuit fault.
What problem does this paper attempt to address?