Effect of Waveform Parameters of High Voltage Square-wave Pulse on Partial Discharge

郭小霞,吴广宁,高波,周力任,曹开江
DOI: https://doi.org/10.3969/j.issn.1009-9239.2008.05.015
2008-01-01
Abstract:The partial discharge(PD) activity of enameled wires for inter-turn insulation of inverter-fed motor winding was studied.The discharge numbers,average discharge quantity and PD patterns under different frequencies and rise times of square waveforms were investigated.The results show that increase of frequency and decrease of rise time both lead to enhancement of PD activity,which can lead to severe degradation of insulations.Due to effect of statistical time lag,it is possible that discharge numbers at every pulse cycle can decrease with the increase of frequency,but it will increase during the same interval time due to enhancement of the number of cycle.At different rise times,the increase of discharge numbers is not proportional to the increase of dv/dt,which relies on available discharge time td.