Corrosion Fatigue Behaviors of Two Biomedical Mg Alloys-Az91d and We43-In Simulated Body Fluid

X. N. Gu,W. R. Zhou,Y. F. Zheng,Y. Cheng,S. C. Wei,S. P. Zhong,T. F. Xi,L. J. Chen
DOI: https://doi.org/10.1016/j.actbio.2010.07.026
IF: 10.633
2010-01-01
Acta Biomaterialia
Abstract:Magnesium alloys have been recently developed as biodegradable implant materials, yet there has been no study concerning their corrosion fatigue properties under cyclic loading. In this study the die-cast AZ91D (A for aluminum 9%, Z for zinc 1% and D for a fourth phase) and extruded WE43 (W for yttrium 4%, E for rare earth mischmetal 3%) alloys were chosen to evaluate their fatigue and corrosion fatigue behaviors in simulated body fluid (SBF). The die-cast AZ91D alloy indicated a fatigue limit of 50MPa at 107 cycles in air compared to 20MPa at 106 cycles tested in SBF at 37°C. A fatigue limit of 110MPa at 107 cycles in air was observed for extruded WE43 alloy compared to 40MPa at 107 cycles tested in SBF at 37°C. The fatigue cracks initiated from the micropores when tested in air and from corrosion pits when tested in SBF, respectively. The overload zone of the extruded WE43 alloy exhibited a ductile fracture mode with deep dimples, in comparison to a brittle fracture mode for the die-cast AZ91D. The corrosion rate of the two experimental alloys increased under cyclic loading compared to that in the static immersion test.
What problem does this paper attempt to address?