Seismic behavior of cast-in-place reinforced concrete hollow slab-shear wall joints

Zhao Zuozhou,Ke Jianghua,Qian Jiaru,Xu Yan
2009-01-01
Abstract:According to principle of "strong joint and weak member",five full-scale cast-in-place reinforced concrete hollow slab-shear wall joint specimens with different reinforcement details have been tested under reversed cyclic loading.From the experimental results it is found that the real failure modes of the five specimens are the same as the designed failure modes.The measured nominal yield loads of the 5 specimens are close to the predicted values.Measured reinforcement strain distributions at the different positions reveal that the cross section of the hollow slab fulfills the assumption of the plan section remaining plan before yield load.Arranging stirrups or prestress tendons in the edge ribs can increase the shear resisting capacity of a hollow slab.The measured ultimate shear displacement angles of the five specimens are larger than 1/40 and the ultimate shear displacement angle of the flexural failure specimens are larger than 1/25.The displacement ductility ratios of the specimens are larger than 4.The hysteretic energy dissipation capacity of each specimen is stable and increases with the maximum control displacement increased.The specimen J5 which simulates the real reinforcement detailing has the largest hysteretic energy dissipation ratio.These test results prove that the cast-in-place reinforced concrete hollow slab-shear wall joints can meet the seismic design code requirements using the proposed design method.