Tests of specimens of double piece prefabricated reinforced concrete hollow-core shear wall

Qian Jiaru,Zhang Weijing,Zhao Fengdong,Li Lurong,Meng Tao,Feng Baochun
2010-01-01
Abstract:Quasi-static test results of four specimens of double piece prefabricated concrete hollowcore shear wall with cast-in-situ boundary elements indicate that: horizontal cracks run through the interface between the wall and the base beam,horizontal cracks distribute almost along the overall height of the boundary elements;diagonal cracks distribute on the whole surface of the prefabricated walls;vertical cracks run through the interface between the boundary element and the prefabricated wall;the failure mode of the specimens is bending-shear type;before the nominal yield,the strain distribution of the vertical reinforcements at the bottom of the wall satisfies the plan assumption;the displacement ductility is greater than 5 and the ultimate drift ratio is greater than 1/100;the hollow-core shear wall specimen can be equalized to the solid wall,its load-carrying capacity can be calculated by the current codes.According to the test results,the suggestions of improving the vertical connections between the prefabricated wall and the cast-in-situ concrete are presented.
What problem does this paper attempt to address?