Quasi-static Test and Simplified Analysis Method of a New Type Precast Shear Wall with Unconnected Vertical Distributed Reinforcements

Qiang Fu,Zhi-Wei Cao,Xian-Dong Liao,Ya-Nan Liu,Shi-Qian Zhang
DOI: https://doi.org/10.1016/j.jobe.2021.103794
IF: 7.144
2021-01-01
Journal of Building Engineering
Abstract:To study the seismic performance of a new type of precast shear wall, four full-scale shear walls, including two cast-in-place specimens and two new types of precast specimens, were tested under low cyclic lateral loading conditions. The vertical distributed reinforcements of the new type of precast shear walls were unconnected to solve the fabrication problems caused by too many connection joints. The capacities, ductility and energy dissipation were studied during the test. In general, the new type of precast shear walls exhibited better seismic performance than the cast-in-place shear walls. During the test, vertical cracks between the cast-in-place boundary elements and the precast panel appeared in precast specimen P-2, which indicated that the failure mode was similar to the damage mechanism of an infilled wall frame. No vertical cracks appeared in precast specimen P-1 whose failure mode was a typical bending failure mode. Then, simplified analysis method based on the strut-and-tie method and the plastic hinge method were proposed for these two failure modes. Finally, finite element analysis was conducted to further evaluate the analysis methods. Good agreement was achieved which indicated the analysis method was rational and accurate.
What problem does this paper attempt to address?