Abstract:The experiments for two specimens under axial compression were carried out to investigate the mechanical behavior of the single prefabricated hollow shear wall.Experimental results indicate that: the failure mode of the specimens is compressive failure;the specimens have quite high axial compressive bearing capacity and small out-of plane displacement,and instability will not occur.Moreover,the axial compressive bearing capacity was calculated by the formula of Code for design of concrete structures,and the calculating results agree well with the test results.At last,nonlinear finite element analysis was carried out,which provided a theoretical base for practical application of the new prefabricated hollow shear wall house structure system.