Tests on seismic behavior of pre-cast shear walls with vertical reinforcements spliced by grout sleeves

Qian Jiaru,Peng Yuanyuan,Zhang Jingming,Qin Heng,Li Jianshu,Liu Guoquan,Zhao Fengdong,Li Lurong
2011-01-01
Abstract:To study seismic behavior of pre-cast reinforced concrete(RC) shear walls with vertical reinforcements spliced by grout sleeves,quasi-static tests of 5 shear wall specimens with shear span ratio of 2.25 were performed.Among them,one is cast-in-site RC wall specimen,two are full pre-cast wall specimens,other two are specimens of two pre-cast walls connected with a cast-in-site RC stripe.The vertical reinforcements of the pre-cast wall specimens are spliced by grout sleeves.The test results indicate that the stresses of the vertical reinforcements can be transferred effectively by grout sleeves.The failure mode of the pre-cast wall specimens is the same as that of the cast-in-site wall specimen,i.e.,tensile yield of reinforcements and compressive failure of concrete.The stiffness and the energy dissipation capacity of the pre-cast wall specimens are similar with those of the cast-in-site wall specimen.The ultimate drift ratios of the pre-cast wall specimens are 1 /59 ~ 1 /48.The current code formulas are suitable for calculating the compressive strength of the pre-cast shear walls.The cast-in-site stripe connects the pre-cast walls to be an unit,the integrity behavior of the rough interface of the side face of the pre-cast wall is better than that of the shear keys.
What problem does this paper attempt to address?