Abstract:Direct contract membrane distillation process was used for high concentrated ammonia simulated wastewater treatment.The initial pH,feed flow and permeate flow were investigated on their influence to the process.The results indicated that increasing initial pH of raw water can significantly enhance the ammonia removal rate,increasing mass transfer coefficient and selectivity.When the initial pH was 12,ammonia removal rate reached 98% in 30 minutes.Raising feed flow got similar regulations.When the initial pH was 11,and the feed flow increased from 400 L/h to 800 L/h,ammonia removal rate increased from 79.8% to 88%.However,the effects of permeate flow on the removal efficiency are not obvious.