Removal of Cyanide and Ammonia Nitrogen from Acrylonitrile Wastewater by Membrane Absorption Process

LIU Hai-yang
DOI: https://doi.org/10.19853/j.zgjsps.1000-4602.2010.15.024
2010-01-01
Abstract:The membrane absorption process was applied to treat acrylonitrile wastewater,and the removal efficiency of cyanide and ammonia nitrogen as well as the influence factors were investigated.The results indicate that the removal efficiency of cyanide can be improved by regulating wastewater to acidic and appropriately increasing NaOH absorption liquid concentration and membrane contact area.The removal rate of cyanide can be improved by appropriately increasing wastewater flow rate.The removal efficiency of cyanide is greatly influenced by removal sequence of cyanide and ammonia nitrogen in wastewater by membrane absorption process.If cyanide first and then ammonia nitrogen are removed,the removal rate of cyanide is below 70%,on the contrary,the removal rate of cyanide is above 85.5%.The membrane absorption process has higher removal efficiency of 93.3% for ammonia nitrogen.
What problem does this paper attempt to address?