Compensating Inverter Output Voltage Error Based on Two-Phase Currents Difference Detection

Zhang Xing,Qu Wenlong,Lu Haifeng,Fan Yang,Cheng Xiaomeng
DOI: https://doi.org/10.3321/j.issn:1000-6753.2008.07.005
2008-01-01
Abstract:In order to improve the performance of AC variable frequency adjustable speed system,a new current polarity detection method is proposed,which is used to compensate the inverter output voltage error caused by the dead time and the non-ideal characteristic of the switch devices.The zero-crossings of the three-phase currents are forecasted in terms of detecting the zero-crossing of two-phase current difference,for example phase A and phase B.Together with the message of phase A current polarity detected at the time of zero-crossings of the two-phase current difference,the current polarities of three-phase at arbitrary moment can be achieved.This method avoids the zero-current clamped phenomenon,and the zero-crossing detection precision is not affected by the odd harmonics.Based on the above polarity detection results,the voltage error produced by the dead time and the non-ideal switching characteristic of IGBT is compensated in an induction motor indirect self control(ISC)system.The compensation of the three-phase voltages are implemented by calculation of the equal time of the voltage error and the feed-forward control of duty cycles of three-phase reference voltages in the real system.Some experiments are carried out,and the experiment results with and without compensation are compared.It shows that the performance of the system is remarkably improved with the proposed method.
What problem does this paper attempt to address?