An Online Self-regulation Dead-time Compensation Strategy

LI Lin-jue,DENG Yan
DOI: https://doi.org/10.3969/j.issn.1000-100X.2013.04.001
2013-01-01
Abstract:Based on the dead-time effect principle,the impacts of zero current zone and none zero current zone of the output inductor are analyzed.The real-time current ripple of the output inductor of a three-phase space vector pulse width modulation(SVPWM) inverter is calculated and rotation reference frame is used to get inductor fundamental current, so the zero current zone and none zero zone can be acquired online.Then different dead-time compensation voltages are used on these two zones to get the best performance of dead-time compensation.The experimental results demonstrate that the harmonic of grid-connected is reduced and the current waveform is improved.