Dead-time Effects Analysis and Elimination for Voltage Source Inverter

YU Zhao-kai,YAN Gang-feng,LIN Zhi-yun
DOI: https://doi.org/10.3969/j.issn.1671-7848.2012.06.037
2012-01-01
Abstract:A novel dead-time elimination method was presented to eliminate the dead-time effect of voltage source inverters.In this method,the traditional modulation strategy was improved,and the switch transistor which should be injected dead-time was chosen according to the direction of the current.As a result,the influence of dead-time on output voltage was removed,so the dead-time effects was eliminated.This method detects the current direction indirectly without adding extra hardware circuit,so it has good practicability.This method has been applied to a servo system of PMSM based on STM32F103RDT6 and its validity has been proved by experiments.
What problem does this paper attempt to address?