Current-Detection-Independent Dead-Time Compensation Method Based on Terminal Voltage A/D Conversion for PWM VSI
Gang Liu,Dafang Wang,Yi Jin,Miaoran Wang,Peng Zhang
DOI: https://doi.org/10.1109/tie.2017.2696480
IF: 7.7
2017-01-01
IEEE Transactions on Industrial Electronics
Abstract:Dead-time insertion increases noise and torque pulsation in motors under open-loop constant V/f control, and it results in instability in motors under sensorless field-orientated control or direct torque control at low speed, degrading performance of motor drive systems. In order to overcome the drawback of dead-time insertion, a novel current-detection-independent dead-time compensation technique based on terminal voltage A/D conversion is proposed in this paper. Both current polarity and compensation time can be extracted from the sampled terminal voltage. Experiments on an induction motor rated at 210 V, 2.2 kW demonstrated the proposed technique can significantly improve the performance of the fixed compensation, online compensation, and even the feedback compensation method. The proposed scheme does not rely on current sensors, and thus can be applied to both open-loop and closed-loop motor drive systems. When combined with the fixed compensation method, the performance of the proposed technique is even comparable with the feedback compensation method within a large frequency range, making it very attractive for open-loop constant V/f drives where current sensors are not available.