Thermal Conductivity Measurement of GlidCop(R)in a Half-life Low-cycle Fatigue State

刘家骅,焦冬生,王桂娟,金建峰,陈海波
2009-01-01
Abstract:The components on the front end of synchrotron radiation beam line are usually used for absorbing high power density of synchrotron radiation.Shanghai Synchrotron Radiation Facility(SSRF),a third-generation synchrotron radiation light source,uses Al2O3-Cu composite material Glidcop~ to manufacture components on the front end.One-dimensional steady longitudinal heat flow method was used to study the thermal conductivity of Glidcop~ in different strain states.Test error was analyzed and a FEM simulation of specimen's temperature distribution was performed to reveal the error source.Test results show that the strain damage accumulation produced by half-life low-cycle fatigue loading does not have obvious effect on the thermal conductivity of Glidcop.
What problem does this paper attempt to address?