Analysis of the Performance of a High Temperature Heat Pump in a Two-stage Cycle

刘昭云,王怀信,郭东奇
2013-01-01
Abstract:When the condensing temperature is in a range from 70 ℃ to 130 ℃ and the temperature rise of the cycle from 40 ℃ to 65 ℃,with HFC245fa serving as the working medium,investigated was the circulation performance of a medium and high temperature heat pump under four modes of a two-stage cycle,namely,incomplete and complete intercooling in a single-and two-stage throttle. It has been found that under the foregoing four modes of the two-stage cycle,the COPs are all obviously higher than that of a single stage cycle,among them,the incomplete intercooling mode in a two-stage throttle can result in a maximal increment in COP,reaching 12. 04%33. 25%. The COP increment will monotonically go up with an increase of the circulation temperature rise,and first decrease and then increase with an increase of the condensate temperature. The two-stage circulation mode can also contribute to lowering the exhaust gas temperature of the compressor and when a wet fluid serves as the working medium,such an effectiveness will be especially remarkable. When the performance benefit and systematic cost are taken into account in a comprehensive way,to introduce the two-stage circulation mode into medium and high temperature heat pumps is feasible.
What problem does this paper attempt to address?