Measurement Of The Gas Sealing In The Planer Solid Oxide Fuel Cell

Wang Huan,Han Min Fang,Wang Qi
DOI: https://doi.org/10.3321/j.issn:1002-185X.2008.z1.135
2008-01-01
Rare Metal Materials and Engineering
Abstract:Sealing has been the difficulty and the key problem in fabrication of the planar solid oxide fuel cell. At present, there is lack of a standard method to test the sealing materials. In this work, a station was designed and a test of the hybride compressive sealing of the glass and mica was performed. The test was conducted using the cell sealed with the phlogopite and glass 12#, at the testing temperature of 800 degrees C, compressive stress of 40 MPa and the pressure gradient of 5 similar to 10 kPa with the leak rate of 0.005 similar to 0.0075 (cm(3).min(-1)).cm(-1). By this process, we got the better sealing results when the thermal expanding coefficient of the mica/glass was closer to that of the electrolyte in the multilayer of mica, glass, electrolyte and alloy interconnects.
What problem does this paper attempt to address?