SEISMIC DESIGN OF BUILDING A OF MINDA PLAZA

Li Yuyu,Xiao Yan,Cao Dayan,Liu Tao
2013-01-01
Abstract:The building A of Minda Plaza was adopted the SRC frame and shear wall structural system.Due to the functional need,the beams were deleted from the spindle-shape outmost frames,where the columns were arranged in an inclined orientation with the principal floor axes.The transfer story was of particular challenge,thus a new type of composite beam with encased built-up double steel sections was designed.The satisfactory performance of the new structural system was validated through quasi-static loading tests and shake-table test.The structure was exhibited to follow the failure mechanism of "strong columns,weak beams,stronger transfer beams,and the strongest connection".The steel reinforced concrete transfer beams with double-steel sections had satisfactory bearing capacity and energy dissipation capacity,suitable to meet the requirements of functional limitation.
What problem does this paper attempt to address?