Pseudo-dynamic testing of hybrid frame with steel beams bolted to CFT columns

W.H. He,Y. Xiao,Y.R. Guo,Y.L. Fan
DOI: https://doi.org/10.1016/j.jcsr.2013.05.005
IF: 4.349
2013-01-01
Journal of Constructional Steel Research
Abstract:This paper presents an experimental study on seismic behavior of a composite structural frame system consisting of concrete filled steel tube columns and steel beams with bolted endplate connections. Based on current seismic provisions and previous research, a ten-story prototype building was designed. Analytical models were developed to predict the elasto-plastic behavior of the prototype frame under a series of ground motion records. A four-seventh scale sub-structure model consisting of two stories and one and half span was constructed and subjected to simulated seismic excitations using pseudo-dynamic hybrid testing method. Results from the tests indicate that the model behavior under the simulated seismic loading was consistent with the expected performances analyzed for different earthquake hazard levels. Finally, quasi-static test and pushover test were also conducted to identify the ultimate failure mode of the testing model. The study shows that the proposed system can offer appropriate strength and adequate ductility required for seismic design.
What problem does this paper attempt to address?