Hybrid moment resisting frame structure with bolted endplate steel beam and reinforced concrete column connections

Yuntian Wu,Yan Xiao,J. C. Anderson,Yurong Guo
2006-01-01
Abstract:In this National Science Foundation sponsored research project, a new type of steel and concrete hybrid moment resisting frame (MRF) system was developed. In the proposed new MRF system, steel beams are connected to either cast in-situ or precast reinforced concrete columns using bolted connections. The new system combines the design merits of horizontal steel elements and vertical reinforced concrete columns to achieve excellent seismic behavior. Several innovative connection details were proposed and studied to ensure adequate constructability. The research involved design and nonlinear analysis of prototype structures and large-scale laboratory testing. This paper summarized the quasi-static test results of two two-third scaled subassembly models with steel beam, reinforced concrete column and footing, which were designed and constructed to simulate the seismic behavior of special moment resisting frame. Copyright © (2006) by Earthquake Engineering Research Institute All rights reserved.