Seismic design on ultra-limit high-rise building for Zhongyu International Plaza

Yu Jinhua,Xiao Zhibin,Liu Zhonghua,Gan Gang
DOI: https://doi.org/10.19701/j.jzjg.2013.02.002
2013-01-01
Abstract:A frame-core wall hybrid system was applied in Zhongyu International Plaza,which exceeds the limit of the code-specification with the height of 204m.In order to guarantee the ductility of the structure,the performance-based seismic design method was adopted and its performance objectives were proposed.Through elastic analysis under frequent earthquake,elastic analysis of critical components under medium earthquake and elastic-plastic dynamic time-history analysis under rare earthquake,seismic performances of the structure and components were verified based on bearing capacity and deformation results under different levels.Structural analysis was carried out by three different calculation software to enhance the reliability of the structural design.The results indicate that the performance objectives can be well realized by proper design measures,and the structure is safe and reliable.
What problem does this paper attempt to address?